How to Read an LED Display Specification Table

By EURYLED

A manufacturer’s specification table is a set of published cells, not a score and not a tender reply form. Each row has a name, a unit, and one value or a range for each model. Read those three things together, and notice when the same page also prints a headline or a category summary that does not match a particular cell. This article walks through common columns — pixel pitch, brightness, ingress protection, refresh rate, control-related information, and weight — using official EURYLED product tables as examples. It does not tell you how to write a bid specification, how to verify a supplier, or how to arrange a room.

Read the heading, the unit, and the model column first

Start with the row title and the unit printed in it, then read across to the model you mean. A category comparison table often prints a band for a whole family. The product table may give a different figure for each model, or two columns for what looks like the same pitch.

The official indoor comparison table summarises H Series brightness as 800–4,500 nits. The H Series product table lists 800, 900 or 1,000 cd/m² on the standard model columns, and a separate column labelled for an H2.5 variant at 4,500 cd/m². If you copy only the family band, you cannot tell which model the high figure belongs to.

The indoor category table lists HD CURVE pixel pitch as P0.94–P1.875. The HD CURVE product table lists 0.9375, 1.25, 1.5625 and 1.875 mm. For a precise pitch, use the product-table cell and record that the category line is rounded.

Pixel pitch is a spacing in millimetres

The usual heading is “Pixel Pitch(mm)”. The number is the centre-to-centre spacing of pixels, in millimetres, for that column. It will affect how the image reads, but recommended distances, formulae, and seating or camera layouts are a separate discussion and are not derived here.

Read the cell as printed. The OW Series outdoor fixed LED display page has two tables: a 250 × 250 mm module family with pitches of 1.95, 2.6, 2.9 and 3.9 mm, and a 480 × 320 mm module family with pitches of 4.4, 5.7, 6.67, 8 and 10 mm. The outdoor category table summarises the series as P1.95–P10, which envelopes those cells but is not a substitute for the pitch you are ordering.

Brightness: notice the unit, any condition, and any range

Brightness is commonly printed in nits or in candelas per square metre (cd/m²), which are the same unit. Official EURYLED category tables use “nits”; several product tables use “Brightness (cd/m²)”. The HD CURVE product table labels the row “Brightness Calibrated”, with 600, 700, 800 and 800 nits across the four columns. “Calibrated” is a condition in the heading. If a sheet does not say how the figure was obtained, do not invent a test method.

Some cells are single numbers; others are ranges. On the W Series product table, W2.9 is listed at 800–1,000 cd/m² and W3.9 at 1,000–1,200 cd/m², while earlier columns are single values such as 700 or 800. Record a range as a range, and ask which point applies if you need a single planning figure.

Outdoor pages can print more than one brightness statement on the same product. On the OW Series page, a feature line reads “Max 10,000nits +”. The body text says that brightness configurations vary by model, with selected OW8 and OW10 options listed at up to 11,000 nits. The 480 × 320 mm table lists OW4.4 at 5,000 cd/m², OW5.7 and OW6.6 at 5,500–10,000, and OW8 and OW10 at 5,500–11,000; the outdoor category table summarises the series as 5,000–11,000 nits; the 250 × 250 mm table lists 5,000 or 6,000 cd/m² by model. Those published lines do not all say the same thing. Do not pick one of them as the official unique value. Note each figure with where it appears.

Ingress protection: read the cell that applies to that model

The protection row is often labelled “IP Rate” on the product table and “Protection” on a category table. The W Series product table lists IP65 for W1.25+GOB and W1.56+GOB, and IP43 for W1.95, W2.5, W2.9 and W3.9. The category table compresses this to “IP65 / IP43”, a family summary, not a promise that every cabinet carries both ratings.

The HD CURVE product table lists “IP65/IP40” in every column, without saying which figure applies to which part of the cabinet. Do not guess. If you need a front and rear rating, ask for that split in writing.

The OW Series tables list IP66 in every column. The same page describes IP66-rated protection against dust and powerful water jets, and says exposure to rain and dust should be considered alongside site drainage, electrical protection and installation conditions. That is published product-page wording only.

Refresh rate, and what the table often omits about control

A “Refresh Rate (HZ)” row is a published drive figure. Many official tables in this set print 7680. The RS Series tables print “≥7680”, a minimum, not a single point. Copy the symbol if it is there. The cell does not, by itself, describe a camera result. A neighbouring “Grey Scale (bit)” row is a different column; do not fold the two together.

Control interfaces may not have their own row. The product tables checked for this article list “Input Voltage (AC)”, for example 110V / 220V, but they do not provide a dedicated row for input format or control protocol. Where the table is silent, look at the surrounding product text and then ask. The W Series page says that content can be managed through supported computer, mobile or USB workflows, depending on the selected controller. Those sentences point to a controller choice; they are not a listed input table. If the quotation needs a named interface, require it as a stated item.

Weight is per cabinet, and sometimes per size option

“Cabinet Weight” is usually a mass for a stated cabinet, not a load capacity for a structure. The H Series table gives 7 kg for the 640 × 480 mm cabinet. The OW Series 480 × 320 mm family lists 25 kg; the 250 × 250 mm family lists 26 kg. The W Series table gives three figures in one cell, 5.8 kg / 3.8 kg / 2.9 kg, next to cabinet dimensions of 1000 / 750 / 500 × 250 mm, so the three masses go with the three sizes. The same table lists thickness as 33 mm / 54 mm, which the product text assigns to single-sided and double-sided cabinets respectively. Read the weight and the size together. Do not turn a cabinet mass into a structural load calculation.

A power row, often “Power Con.(W/m²) (Max / Avg)”, is a published pair of figures. How those figures are used for distribution or cooling is a separate subject and is not developed here.

Use the table as a snapshot, not as your specification

When you transcribe a cell, transcribe the heading, the unit, the model, and whether the value is a point or a range. If two places on the same page disagree, record both and ask which configuration you are being offered. If a column is blank, say it is blank. A catalogue table is a convenient way to compare published options. It is not the technical specification for a tender, and it should not be copied into a bid return as if the buyer had written those requirements. Several EURYLED tables also note that specifications and photos are subject to change without prior notice. Read the sheet you have, in the units it uses, under the conditions it actually names.

About the author

Shenzhen EURYLED Electronics Company Limited builds indoor and outdoor LED display systems. This article is a technical briefing on reading published LED display specification tables. It is not a product launch and is not a paid placement.